Specifies a rigid type.
If you use Valve Flange Database , then the software sets the value for Rigid Type. For more information, see Valve Flange Database.
The software graphically displays the rigid type in the model view.
Unspecified |
Valve |
Flange |
Flange Pair |
Flanged Valve |
When you select Flange-Valve-Flange in Valve Flange Database , the software creates a valve and a pair of flanges. For more information, see Valve and Flange Database: <database name> Dialog Box.
If you have not specified a value for Element Name, then the software defines Element Name with the value for Rigid Type. No change is made to Element Name when Rigid Type is Unspecified.