Stresses Tab - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Specifies filter criteria for the various stress output reports (Stresses, Stresses Extended, and Stress Summary). You can set up filter criteria based on Axial, Bending, Torsion, Hoop, Max 3D, Code and Allowable stress factors in combination with the magnitude. In addition, you can filter stress data on the reports based on SIFs (in- and out-of-plane), and on a percentage of stress. Use the operator boxes to specify comparison operators for the filter values.

For example, if you set the Stresses filter class Percent box to >70, the software filters the stress-related reports to show only elements having greater than a 70 percent stress.

For more information on filtering output reports, see Filters Dialog Box and Filter Reports.

The software does not apply report-specific filter criteria to custom reports that use combination classes.