Bolt Allowable @ Design Temperature - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Specifies the allowable stress for the bolt material at the design temperature. This value is only required if an ASME stress analysis of the flange is to be performed.

Typical units (depending on your unit system):

  • lb/in2

  • KPa

  • N/mm²

This value is available in the ASME Sect. VIII Div. 1 material database delivered with the software. You can access the database by typing a material name in the Flange Material box or by clicking Browse and selecting a material in the Material Selection list.

When you select a material in the database, fill in the spaces for any material values where the defaults are not sufficient. Press F1 for guidance on the material values.