Specifies the thickness of the large end of the hub, g1..It can be the same as Small Hub Thickness.

Typical units (depending on your unit system):

  • in

  • mm

  • cm

For flange geometries without hubs, this thickness can be entered as zero, or left blank.

This value is required only for ASME stress calculations. It is available in the flange ANSI B16.5/API dimensional database. You can access the flange database properties by pressing Ctrl+F from any data cell in the Flange tab.