Creates earthquake spectra (horizontal and vertical) according to the 1997 Uniform Building Code.
The horizontal design response spectrum is based on UBC Figure 16-3 shown below.
Ts=Cv/2.5Ca & T0=Ts/5
The vertical spectrum is to 50% of I•Ca across the entire period range.