PI Event Frames can have assets (which are associated with areas) linked to them. This means that an Operations Logbook entry generated from an Event Frame can have the same area information as the asset associated with the Event Frame. This is only possible when:
-
The PI asset is available in the j5 Asset Register, where the asset name is the same as the GUID of the Element in AF.
To show GUIDs in the PI system explorer: Right-click on the status bar and select Show Unique ID. The GUID is then displayed in the status bar on the right.
-
The PI asset has been added as a Referenced Element to the Event Frame in the PI System Explorer. In most cases, this is the element that has triggered the event.