Code Updates
-
No changes.
Configuration
-
Added support for API-650 13th Edition, March 2020, including:
-
API 650 13th Ed.: 5.9.5.3 Section Modulus of the Top Wind Girder (CR-TX-35343)
-
API 650 13th Ed.: 5.9.5.4 Moment of Inertia (CR-TX-35345)
-
API 650 13th Ed.: 5.9.6.1 Maximum Height of Unstiffened Shell (CR-TX-35346)
-
API 650 13th Ed.: E.2.2 Cd Definition Research (CR-TX-35347)
-
API 650 13th Ed.: E.6.2.2.3 Research (CR-TX-35348)
-
API 653, 5th Ed., Addendum 2, May 2020 (CR-TX-35348)
(RI-TX-35121)
-
Input Processor and Analysis
-
Improved data entry on the wind pressure vs. elevation table. (CR-TX-33232)
-
Added the option to include rafter weight acting with the roof weight for the maximum design pressure calculations. (CR-TX-33233)
Output Processor and Reports
-
Allowed the wind pressure to decrease with elevation. The Wind Calculations report displays a warning message if at least one wind pressure entry decreased with elevation. (CR-TX-33231)
Help
-
Updated help for the roof specification Net Area Scratchpad (F.2) to show sketches for details a through k of API-650 Figure F.2. (CR-TX-33504)
-
Updated the API 2000 references for Venting Requirements. (CR-TX-34783)