The following attributes specify the configurations for the insulation support.

Attribute Name

Description

Implementation Details

IJUAhs_InsulLength::
InsulLength

Specifies the length of the insulation.

The default units are specified in the CustomInterface worksheet. Otherwise, specify the units (for example, 25, 25mm, 3in.).

Configuration Attributes_Insulation_IJUAhs_InsulLength

IJUAhs_InsulLengthRl::
InsulLengthRule

Specifies a HgrSupportRule that returns the insulation length value.

The hanger rule must be present in the catalog and must be a rule name.

To specify the offset using InsulLength, do not type any value for this property.

Example:

Rule Name: InsLenSel

IJUAhs_InsulLengthSel::
InsulLengthSelection

Overrides the codelist value that determines the origin of the selection. This property uses the hsSelection codelist.

hsSelection:

1 - By Rule

2 - By Input

IJUAhs_InsulOffset::InsulOffset

Specifies the offset distance of insulation from route

IJUAhs_InsulOffsetRl::InsulOffsetRule

Specifies a HgrSupportRule that returns the insulation offset value.

The hanger rule must be present in the catalog and must be a rule name.

IJUAhs_InsulOffsetSel::InsulOffsetSel

Overrides the codelist value that determines the origin of the selection. This property uses the hsSelection codelist.

hsSelection:

1 - By Rule

2 - By Input