Steel Connection Properties (L-Frame) - Intergraph Smart Reference Data Standard Database - Version 12.4 - Help - Hexagon

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Smart 3D Version
13.1
Standard Database for Smart Reference Data Version
12.4

Attribute Name

Description

Implementation Details

IJUAhsCornerConn1Type::

Connection1Type

Specifies the type of connection to use when connecting Leg1 to Member1. Applicable to U, L, T, types only. Allowed values are from the hsSteelCornerConnection or hsSteelTeeConnection codelist in the HS_S3DAssy_Codelist.xls workbook.

These values are:

0 – Butted

1 – Lapped

2 – Nested

3 – Coped

4 - Fitted

IJUAhsCornerConn1Swap::

Connection1Swap

Specifies whether the connection between Leg1 and Member1 is swapped so that they are connected in the reversed order. Applicable to U, L, types only. This property accepts two values, 0 and 1.

IJUAhsCornerConn1Mirror::Connection1Mirror

Specifies whether to mirror the connection between Leg1 and Member1 if the connection type has a valid mirrored configuration. For a lapped connection, the steel section laps to the opposite side. For a nested connection, the steel section nests into the opposite corner if one exists.

This property accepts Boolean values 0 and 1 and is applicable to U, L, T, and Box Frame types only.

0 (False)

image249

i - Lapped Connection

1 (True)

image250

ii - Mirrored Lapped Connection