You place a gusset between a vertical leg support and a corresponding horizontal member. Additionally, you can place a gusset between a vertical leg and the supporting objects or the base plate.
-
You can place gussets only on Pipe, W, or C section leg members.
-
You can place stiffeners only on horizontal member W and C sections.
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsGussetPart:: |
Specifies the gusset part number or the part class to use for the support. The software places the gusset between the horizontal member and the vertical member. |
Supported Part Class ProgID Type: Options: Specify the part number. Alternatively, specify the part class. Use a HgrRule to obtain the part. |
IJUAhsGussetRl:: |
Specifies the rule name the software uses to select the GussetPart part number. |
|
IJUAhsFMGussetQty:: |
Specifies the codelist value that defines the quantity of gusset plates. |
hsGussetCount1 Supported values: 0, 2 |
IJUAhsGusset2Part:: |
Specifies the gusset part number or the part class to use for the support. The software places the gusset between the vertical member and the supporting object or base plate. |
Supported Part Class ProgID Type: Options: Specify the part number. Alternatively, specify the part class. Use a HgrRule to obtain the part. |
IJUAhsGusset2Rl:: |
Specifies the rule name the software uses to select the Gusset2Part part number. |
|
IJUAhsFMGusset2Qty:: |
Specifies the codelist value that defines the quantity of Gusset2 plates. |
hsGussetCount2 Supported values: 0, 2, 4 |
IJUAhsGusset2Flip:: |
Specifies whether the software flips the gusset location when Gusset2 = 2. By default, the software does not flip the gusset location. |
Supported values: False - not flipped; beside flange
True - flipped; beside web
|
IJUAhsStiffener:: |
Specifies the stiffener part number or the part class to use for the support. The software places the stiffener on the horizontal member. |
Supported Part Class ProgID Type: Specify the part number. Alternatively, specify the part class. Use a HgrRule to obtain the part. |
IJUAhsStiffenerRl:: |
Specifies the rule name the software uses to select the StiffenerPart part number. |
|
IJUAhsStiffenerQty:: |
Specifies the codelist value that defines the number of stiffener sets required at each placement location. |
hsStiffenerCount Supported values: 0, 1, 2 The following images are for a C section. Value = 1 Value = 2 The following images are for a W section. Value = 1 Value = 2 |
IJUAhsStiffenerLoc:: |
Specifies the codelist value that defines where the software places the stiffener. By default, the software places the stiffener above the leg steel. |
hsStiffenerLocation Supported values: 1, 2, 3, 4 1 - Above leg steel (default) 2 - Below main pipe 3 - Below each pipe 4 - All (above leg and each pipe) |
IJUAhsStiffenSpaceL:: |
Specifies the distance between two stiffeners above the leg when StiffenerQuantity=2. |
|
IJUAhsStiffenSpaceP:: |
Specifies the distance between two stiffeners below pipes when StiffenerQuantity=2. |
|
IJUAhsStiffenSpaceLR1:: |
Specifies a rule name that returns the distance between two stiffeners above the leg and below pipes. |
|
IJUAhsStiffenSpacePR1:: |
||
IJUAhsStiffenSpaceLDef:: |
Specifies how the software defines and measures the distance between two stiffeners. |
hsStiffenerSpacing Supported values: 1, 2, 3 1 - Center of stiffener plates 2 - Inside edge of stiffener plates 3 - Outside edge of stiffener plates |
IJUAhsStiffenSpacePDef:: |