These properties specify and customize the attachments in the support.
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsFrPipeAtt1::PipeAtt1Part |
Specifies the part number or part class for the first pipe attachment. For example, U-Bolt part number can be used as PipeAtt1Part. To select the part number using PipeAtt1Rule, do not type any value for this property. |
|
IJUAhsFrPipeAtt1Rl::PipeAtt1Rule |
Defines an HgrSupportRule that returns a pipe attachment part number. The hanger rule must exist in the catalog; it can be the name of a rule or a rule ProgID. To select the part number directly using PipeAtt1Part, do not type any value for this property. |
Option 1 - Specify a part number or part class directly. Option 2 - Use HgrRule to get the part. The base support is a mandatory part. Specify either a Member1Part or Member1Rule. |
IJUAhsFrPipeAtt1Qty::PipeAtt1Quantity |
Specifies the number of PipeAtt1Part to be included in the support. Usually, 1 or 2. |
|
IJUAhsFrPipeAxlOffset::PipeAxlOffset |
Specifies the axial offset value for PipeAtt1Part along the pipe. |
|
IJUAhsFrPipeAxlOffsetRl::PipeAxlOffsetRl |
Defines an HgrSupportRule that returns a pipe attachment axial offset value. |
|
IJUAhsBasePlate1::BasePlate1Part |
Specifies the part number or part class of the first base plate. This must be a SmartPart 2 Port Plate. To select the part using BasePlate1Rule, do not type any value for this property. |
|
IJUAhsBasePlate1Rl::BasePlate1Rule |
Defines an HgrSupportRule that returns a part number or part class to use for the base plate. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To select the part directly using BasePlate1Part, do not type any value for this property. |
|
IJUAhsBasePlate1Ang::BasePlate1Angle |
Specifies the angle that BasePlate1 should be rotated about the Z-axis of the port to which the plate is attached (either BeginFace or EndFace). |
|
IJUAhsBasePlate1Off::BasePlate1Offset |
Specifies the distance by which the base plate should be offset from leg1. BasePlate1Offset is applicable only when StructureConnection is set to either Lapped or Lapped-Opposite. |
|
IJUAhsFrVesselClip::VesselPad |
Specifies the part number or the part class of the Vessel Pad on Leg1, which connects both base plate and Vessel Pad. |
Vessel Pads are optional parts. To exclude VesselPads, do not enter any values for these attributes. |
IJUAhsFrVesselClip::GussetPlate |
Specifies the part number or the part class of the VesselClip Gusset plate on Leg1, which connects both base plate and Vessel Pad. |
Vessel Pads are optional parts. To exclude VesselPads, do not enter any values for these attributes. |
IJUAhsFrVesselClip::OnEquipment |
Specifies the support placement on vessels. |
1 Places on the vessel 0 Does not places on the vessel |
IJUAhsFrGrout::GroutPart |
Specifies the part number or the part class of the grout part. For example Plate part number. To select the part using GroutRule, do not type any value for this property. |
|
IJUAhsFrGroutRl::GroutRule |
Defines an HgrSupportRule. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. To specify the grout part directly using GroutPart, do not type any value for this property. |
|
IJUAhsFrGroutTh::GroutThickness |
Specifies the thickness of the GroutPart. |
|
IJUAhsBolt1::Bolt1Part |
Specifies the part number or the part class of the Bolt part. For example Plate part number. To select the part using Bolt1Rule, do not type any value for this property. |
|
IJUAhsBolt1Rl::Bolt1Rule |
Defines an HgrSupportRule. The hanger rule must exist in the catalog; it can be a rule name or a ProgID. |
|
IJUAhsBolt1Qty::Bolt1Quantity |
Specifies the quantity of the Bolt1Part. |
|
IJUAhsBolt1Offset1::Bolt1Offset1 |
Specifies the offset1 value of the Bolt1Part. |
|
IJUAhsBolt1Offset2::Bolt1Offset2 |
Specifies the offset2 value of the Bolt2Part. |