Stanchion Dimension Attributes - Intergraph Smart Reference Data Standard Database - Version 12.0 - Help - Hexagon PPM

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help (2020)

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Standard Database for Smart Reference Data Version
2020 (12.0)

The Stanchion assembly uses the following attributes:

Name

User Name

Category

On Property Page

Read Only

StanchionAngle

Stanchion Angle

Dimensions

Yes

No

OffsetFromStructure

Offset From Structure

Dimensions

Yes

No

StanchionGap

Stanchion Gap

Dimensions

Yes

No

StanchionLength

Stanchion Length

Dimensions

Yes

No

Attribute Name

Description

Implementation Details

IJUAhsStanchionAngle::
StanchionAngle

Specifies the orientation of the stanchion support along its vertical axis.

Use the following values:

Steel Member - Angle = 0 or 180

Stanchion - Dimension Attributes - Stanchion Angle - 0-180

Steel Member - Angle = 90 or 270

Stanchion - Dimension Attributes - Stanchion Angle - 90-270

IJUAhsStanchionOffset::
OffsetFromStructure

Specifies the offset from the face of the supporting object.

This attribute value must be applied below the bottom most part of the support.

Stanchion - Dimension Attributes - Stanchion Offset

IJUAhsStachionGap::
StanchionGap

Specifies the gap between the route and the top of the stanchion.

If you specify a value for stanchion length, the software does not use the stanchion gap value.

If you do not specify a value for stanchion gap or for stanchion length, the software uses the part attributes.

Use the following definitions:

1 = Pipe centerline - Horizontal pipe

Stanchion - Dimension Attributes - Stanchion Gap

2 = Bottom of pipe - Horizontal pipe

Stanchion - Dimension Attributes - Stanchion Gap - 2

3 = Top of turn

Stanchion - Dimension Attributes - Stanchion Gap - 3

4 = From SmartPart StanGap attribute

IJUAhsStanchionLength::
StanchionLength

Specifies the length of the stanchion.

If you specify a value for stanchion length, the software does not use the stanchion gap value.

Use the following definitions:

1 = Bottom to top of support (includes all parts)

Stanchion - Dimension Attributes - Stanchion Length - 1

2 = Bottom of base plate to top of support

Stanchion - Dimension Attributes - Stanchion Length - 2

3 = Bottom of SmartPart to top

Stanchion - Dimension Attributes - Stanchion Length - 3