Box Frame support uses all the General Attributes specified in Common Attributes and the following additional general attributes:

Name

User Name

Category

On Property Page

Read Only

FrameType

Frame Type

Standard

No

Yes

FrameOrientation

Frame Orientation

Standard

Yes

No

MirrorFrame

Mirror Frame

Standard

Yes

No

IncludeInsulation

Include Insulation

Standard

Yes

No

StructureConnection

Structure Connection

Standard

Yes

No

StructureConnection2

Structure Connection 2

Standard

Yes

No

Attribute Name

Description

Implementation Details

IJUAhsFrameType::
FrameType

Specifies the codelist value that defines the Frame shape.

hsFrameType:

6 - Box Frame

IJUAhsFrameOrientation::
FrameOrientation

Specifies a codelist value that determines the orientation of the Frame support with respect to the supporting object or the global coordinate system.

hsFrameOrientation:

1 - Direct towards the supporting object

Frame Orientation Box Support - Frame Orientation - Direct 2

2 - Orthogonal to the global coordinate system

Box Frame - Frame Orientation - Ortho 1 Box Frame - Frame Orientation - Ortho 2

3 - Tangent to the first and last selected pipes

Box Frame - Frame Orientation - Tangent 1 Box Frame - Frame Orientation - Tangent 2

IJUAhsFrameConfiguration:: FrameConfiguration

Defines the initial frame configuration on placement. This property is applicable only to U, L and T-Frames types. You can change the configuration after placing the support by clicking Change Support Configuration on the ribbon.

Accepted values are:

1 - Frame support placed on the far side of the pipe.

2 - Frame support placed on the closest side of the pipe.

IJUAhsMirrorFrame::
MirrorFrame

Mirrors the Box Frame support about the bounding box.

0 - False

Box Frame - Mirror Frame - 0 - False

1 - True

Box Frame - MirrorFrame - 1 - True

IJUAhsIncludeInsulation::
IncludeInsulation

Specifies whether the Box Frame must adjust its size to include pipe insulation.

0 - False

Box Frame - IncludeInsulation - 0 - False

1 - True

Box Frame - IncludeInsulation - 0 - False

IJUAhsStructureConn::
StructureConnection

Specifies a codelist value that determines how a hanger beam part connects to the structure.

1 - Normal

2 - Lapped

3 - Lapped-Opposite