The following attributes specify the configurations for a Limit Stop support:

Name

User Name

OA

Category

On Property Page

Read Only

ShoeHeight

Shoe - Height

Yes

Dimensions

Yes

No

Angle1

Stop - Angle 1

Yes

Dimensions

Yes

No

Angle2

Stop - Angle 2

Yes

Dimensions

Yes

No

ConnectTo

Connect To

Yes

Dimensions

Yes

No

SpanOver

Span Over

Yes

Dimensions

Yes

No

StructureConnection

Structure Connection

No

Dimensions

Yes

No

Attribute Name

Description

Implementation Details

IJUAhs_StopShoeHeight::
ShoeHeight

Specifies the height of the shoe that moves the Limit Stop either up or down.

This is applicable only of the Limit Stop is connected to the pipe.

Illustration of Limit Stop Configuration - Shoe Height

IJUAhs_StopAngle1::Angle1

IJUAhs_StopAngle2::Angle2

Specifies the angle for the rotation of the first or the second Limit Stop around the longitudinal axis.

hsSteelOrientationAngle

0, 90, 180, or 270 degrees

IJUAhs_StopAngle3::Angle3

Specifies the angle for the rotation of the first or the second Limit Stop around the axial axis.

This property is valid only for the steel sections.

hsSteelOrientation090

0 degrees

Limit Stop Configuration - Angle3 - 0 Degrees

90 degrees

Limit Stop Configuration - Angle3 - 90 Degrees

IJUAhs_StopConnectTo::
ConnectTo

Specifies the codelist value that determines whether the Limit Stop connects to the pipe or the supporting steel.

hsStopConnectTo

1 = Pipe

Illustration of Limit Stop Configuration - Connect To Pipe

2 = Structure

Illustration of Limit Stop Configuration - Connect To Structure

IJUAhs_StopSpanOver::
SpanOver

Specifies the value for span measurement.

This is valid only when the Structure Connection is set to 1.

hsStopSpanOver

1 = Supporting Width

Illustration of Limit Stop Configuration - Span Over - Supporting Width

2 = Supporting Depth

Illustration of Limit Stop Configuration - Span Over - Supporting Depth

IJUAhs_StopStructConn::
StructureConnection

Specifies the Limit Stop location, and the position from where the Limit Stop clearance is measured from.

1 = Below supporting structure

The Limit Stop is placed below the supporting structure and the width is used as Limit Stop clearance measurement.

Illustration of Limit Stop Attribute - Structure Connection - Below

2 = Above supporting structure

The Limit Stop is placed above the supporting structure and the starting point for clearance is taken as zero.

Use above supporting structure when the pipe and supporting structure are parallel.

Illustration of Limit Stop Attribute - Structure Connection - Above