General Attributes - Intergraph Smart Reference Data Standard Database - Version 12.0 - Help - Hexagon PPM

Standard Database for Intergraph Smart Reference Data Hangers and Supports Help (2020)

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Standard Database for Smart Reference Data Version
2020 (12.0)

Attribute Name

Description

Implementation Details

IJUAhsSupportNumber::SupportNumber

Defines the support detail number as specified on the support specification. This value is used by the default BOM function when generating the BOM Description for the support.

IJUAhsSteelStandard::SteelStandard

Defines the steel standard used by the support. If external rules were written to select the steel section, this attribute would be used to determine the standard to use.

IJUAhsFrameType::FrameType

Defines the type of the frame shape. This attribute is used by rules to determine what type of frame the support is. Additional code-List values can be added as required. Accepted values from the hsFrameType codelist in the HS_S3DAssy_Codelist.xls workbook are shown beside:

5 - U-Frame

uframe1

IJUAhsFrameOrientation::FrameOrientation

Defines the frame support orientation with respect to the supporting object or the global coordinate system. Accepted values from the hsFrameOrientation codelist in the HS_S3DAssy_Codelist.xls workbook are:

1 - Direct - Frame support orients directly towards the supporting object.

Direct Orientation to planar object

image171

Direct Orientation to Curved Object

image172

2 - Orthogonal - Frame support orients orthogonally to the global coordinate system.

Orthogonal orientation to planar object

image173

Orthogonal orientation to curved object

image174

3 - Tangent - Frame support orients tangent to the first and last selected pipes.

Tangent orientation to planar object

image175

Tangent orientation to curved object

image176

IJUAhsMirrorFrame::MirrorFrame

Mirrors the frame support about the bounding box. Accepted values are like::

0 - False

image178

1 - True

image181

IJUAhsIncludeInsulation::IncludeInsulation

Specifies whether the frame should adjust its size to include pipe insulation.

0 - False

image182

1 - True

image183

IJUAhsStructureConn::StructureConnection

Specifies how the hanger beam part is connected to the structure. Allowed values in the codelist are:

Normal

Lapped

Lapped-Opposite