You can run I-Data Integrator using the command line. The software runs silently, writing all output to a specified log file. You can specify a series of command line parameters to control the execution of the software.
Syntax
I-Data Integrator/s style file /o output directory [/l log file ] [/f output format] [/c]
/s
Specifies the path to the style file (FLS or OPT). Spaces are permitted in the path. This parameter is required.
/s C:\SampleProj\SampleProject\Final-Basic\ISOGEN.fls
/o
Specifies the path to the folder to contain the output files. Spaces are permitted in the path name. This parameter is required.
/o C:\SampleProj\SampleProject\Final-Basic\Reports
/l
Specifies a name for log file. This parameter is optional. If it is not specified, the log file is written to the style file folder, with the name matconvert.log.
/l C:\SampleProj\SampleProject\Final-Basic\projectA.log
/f
Specifies the output format. This parameter is optional. If it is not specified, the first (default) format from the list displayed on the SmartPlant Isometrics I- Data Integrator window is used. This string is not case sensitive. For example, ACCESS is the same as access and Access.
/f Access
/f Delimited
/c
Optional clear flag (no parameters). If present on the command line, I-Data Integrator automatically deletes all the Isogen data files after converting them to the specified format.
/u
Species the user configuration file used to pass the name of the user-specified XML configuration file to I-Data Integrator when it is being run in batch.
/u user_output_options_file
Example Log File
I-Data Integrator executed at 07/01/02 15:41:58
Configuration file = C:\SampleIsoDir\S5Tutorial\data\I-Data\Default.xml
Style = C:\SampleIsoDir\S5Tutorial\Final-Basic\ISOGEN.fls
Output Format = Access
Output directory = C:\SampleIsoDir\S5Tutorial\Final-Basic\Reports
Delete ISOGEN data = True
Data written to C:\SampleIsoDir\S5Tutorial\Final-Basic\Reports\Materials.mdb
Table : Pipeline
Table : Components