On the Instrument Types dialog box, from the Process function list, select Control Valve.
-
Scroll down the Instrument Type list and select instrument type FV (with description CONTROL VALVE).
-
Click Profile to open the Instrument Type Profile dialog box.
-
On the General tab, do the following:
-
In the Instrument specifications group box, select Include instrument specification.
-
From the Specification form list, select Control Valve 1.
-
In the Hook-ups group box, select Include hook-ups and Include in BOM.
-
In the Location group box, select Include location and from the list, select Field.
The General tab of the Instrument Type Profile dialog box should now appear as shown:
-
-
Click OK to return to the Instrument Types dialog box.
-
Click Apply.
-
Select instrument type LV (with description CONTROL VALVE) and copy the profile definitions from FV.