The following table lists solutions to common problems that can happen during the conversion process.

Message

Meaning / Solution

No SKEY found for Model Code B23. It has been set to NCFL:

ModelCode B23 in ISOMAP table does not have a corresponding SKEY.

Can't Find Physical Data File C:\catalogS\BAYERDATA\Physical\TDB23_39_555_130 ….

The physical data files do not exist. Check the column codes to ensure the correct files are being sought.

No Description for Commodity Code 655_883

A description for this component does not exist in the Short Descriptions File. Check the column codes to ensure the correct Commodity Code is being generated.

No Dimensions for Component 768803.034.9, NS 26…...

Physical data does not exist for this component. Check the bore and data file.

No Bolt Record in PCSD for component with NS .5, Rating 150

No bolt record can be found for a particular bolted component. Check units / settings.

Dimension mapping '' for SKEY ELBW is illegal, …..

An Illegal dimension map has been specified. Check the Equation Mapping file / ISOMAP table.

Invalid mapping for component 6Q2C23_1 Output O4 ……

The requested Output column does not exist in the physical file. Check the equation.map file.

Cannot Determine Radius for Trimable Elbow (90 Degree Assumed)

The angle for the trimmable elbow could not be found in the description. The software has assumed it to be 90 Degrees.

Information - Radius for Trimable Elbow (90 Degree Assumed)

The angle as defined by ‘ASTRING’ has not been found; however, more extensive checks have enabled the software to make a decision on the angle.