The following dimensions are used by both SmartPart Base Plate and Rich Hanger Beam Base Plate data-driven assemblies:
Name |
User Name |
Category |
On Property Page |
Read Only |
---|---|---|---|---|
OffsetFromStructure |
Offset From Structure |
Dimensions |
Yes |
No |
OffsetFromStructureRl |
Offset From Structure Rule |
Dimensions |
No |
Yes |
AnchorBoltX |
Anchor Bolt X |
Dimensions |
Yes |
No |
AnchorBoltXRule |
Anchor Bolt X Rule |
Dimensions |
No |
Yes |
AnchorBoltXDefinition |
Anchor Bolt X Definition |
Dimensions |
No |
Yes |
AnchorBoltXSelection |
Anchor Bolt X Selection |
Dimensions |
No |
Yes |
AnchorBoltY |
Anchor Bolt Y |
Dimensions |
Yes |
No |
AnchorBoltYRule |
Anchor Bolt Y Rule |
Dimensions |
No |
Yes |
AnchorBoltYDefinition |
Anchor Bolt Y Definition |
Dimensions |
No |
Yes |
AnchorBoltYSelection |
Anchor Bolt Y Selection |
Dimensions |
No |
Yes |
AnchorBoltZ |
Anchor Bolt Z |
Dimensions |
Yes |
No |
AnchorBoltZRule |
Anchor Bolt Z Rule |
Dimensions |
No |
Yes |
AnchorBoltZDefinition |
Anchor Bolt Z Definition |
Dimensions |
No |
Yes |
AnchorBoltZSelection |
Anchor Bolt Z Selection |
Dimensions |
No |
Yes |
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhsStanchionOffset:: |
Specifies the offset from bottom of the base plate to the face of the supporting object. |
|
IJUAhsStanchionOffsetRl:: |
Specifies the HgrSupportRule that returns the value for the offset from structure. The hanger rule must exist in the catalog, and must be the name of a rule. To select the offset from structure using OffsetFromStructure, do not specify any value for this property. |
For example: Rule Name: OffStructBySize Rule ProgID: HS_S3DRules, HS_S3DRules. |
IJUAhsAnchorBoltX:: |
Specifies the offset for anchor bolt X. |
The CustomInterfaces sheet has the default units. This sheet exists in AllCodeLists.xls. Otherwise, specify the below mentioned units:
|
IJUAhsAnchorBoltXRl:: |
Specifies the HgrSupportRule that returns the value for the offset for anchor bolt X. The hanger rule must exist in the catalog, and must be the name of a rule. To select the X offset using AnchorBoltX, do not specify any value for this property. |
For example: Rule Name: BoltOffXBySize Rule ProgID: HS_S3DRules, HS_S3DRules. |
IJUAhsAnchorBoltXDef:: |
Specifies the definition of the offset for anchor bolt X. If you set a value for AnchorBoltX and do not specify a definition, the software throws an error. |
The following definitions are supported: 1 - Offset from baseplate edge 2 - Offset between bolts 3 - Offset from centerline of baseplate |
IJUAhsAnchorBoltY:: |
Specifies the offset for anchor bolt Y. |
The CustomInterfaces sheet has the default units. This sheet exists in AllCodeLists.xls. Otherwise, specify the below mentioned units:
|
IJUAhsAnchorBoltYRl:: |
Specifies the HgrSupportRule that returns the value for the offset for anchor bolt Y. The hanger rule must exist in the catalog, and must be the name of a rule. To select the Y offset using AnchorBoltY, do not specify any value for this property. |
For example: Rule Name: BoltOffYBySize Rule ProgID: HS_S3DRules, HS_S3DRules. |
IJUAhsAnchorBoltYDef:: |
Specifies the definition of the offset for anchor bolt Y. If you set a value for AnchorBoltY and do not specify a definition, the software throws an error. |
The assemblies support the following definitions: 1 - Offset from baseplate edge 2 - Offset between bolts 3 – Offset from centerline of baseplate |
IJUAhsAnchorBoltZ:: |
Specifies the offset for anchor bolt Z. |
Use the following definitions: 1 - Distance above plate 2 - Distance from the center of plate to the center of the bolt |
IJUAhsAnchorBoltZRl:: |
Specifies the HgrSupportRule that returns the value for the offset for anchor bolt Z. The hanger rule must exist in the catalog, and must be the name of a rule. To select the Z offset using AnchorBoltZ, do not specify any value for this property. |
For example: Rule Name: BoltOffZBySize Rule ProgID: HS_S3DRules, HS_S3DRules. |
IJUAhsAnchorBoltZDef:: |
Specifies the definition of the offset for anchor bolt Z. If you set a value for AnchorBoltZ and do not specify a definition, the software throws an error. |
The assemblies support the following definitions: 1 - Distance above plate 2 - Distance from center of plate to center of bolt |