A Lifting Lug uses the following configuration attributes:
Attribute Name |
Description |
Implementation Details |
---|---|---|
IJUAhs_LugDblSpace:: |
Specifies the offset value for adding a second lifting lug. |
1 - Space between Lifting Lug inside edges |
IJUAhs_LiftingLugGap:: |
Specifies a value for the gap between the pipe and the Lifting Lug. The Lifting Lug is offset by this value. |
1 - Space between pipe and Lifting Lug inside edges |
IJUAhs_RepadPart::RepadPart |
Specifies the Repad part number or part class to use for the support. |
|
IJUAhs_RepadRl::RepadRule |
Specifies the HgrSupportRule that returns a Repad part for the support. |
|
IJUAhs_RepadTh:: |
Specifies the total thickness of the Repad. |
Default units are specified on the CustomInterfaces sheet. Specify the units otherwise. IE: |
IJUAhs_RepadThRl:: |
An HgrSupportRule that returns a numerical value for RepadThickness. The Hanger Rule should be present in the catalog; it can be a rule Name or ProgID. If you intend to use RepadThickness to directly specify the length, then this attribute should be left blank. |
IE: RepadThFromPipeWall Rule ProgID: HS_S3DRules. RepadThFromPipeWall |
IJUAhs_RepadThSel:: |
Determine which attribute is used to set RepadThickness. If no value is given, the RepadThickness attribute will be used by default. If the Dummy is being used as a sub assembly, check to see if the RepadThicknessOverride attribute has been set by the parent assembly. |
hsSelection 1 = By Rule 2 = By Input |
IJUAhs_RepadThDef:: |
The definition of the RepadThickness value. This attributes specifies how the attachment should be measured. If a value is set for RepadThickness but no definition is given, an error will occur. |
Supported Values 1 = Repad Thickness (direct) |
For more information on how to use the configuration attributes, see Input Values.