Part Attributes - Intergraph Smart Reference Data Standard Database - Version 12.3 - Help - Hexagon PPM

SDB for SRD Hangers and Supports Help 12.3

Language
English
Product
Intergraph Smart Reference Data Standard Database
Search by Category
Help
Smart 3D Version
13
Standard Database for Smart Reference Data Version
12.3

The following table lists part attributes for a Limit Stop support:

Name

User Name

OA

Category

On Property Page

Read Only

StopPart

Stop

No

Standard

No

No

StopRule

Stop – Rule

No

Standard

No

No

StopSide

Stop – Side

No

Dimensions

Yes

No

StopClearance

Stop – Clearance

Yes

Dimensions

Yes

No

Attribute Name

Description

Implementation Details

IJUAhs_Stop::StopPart

Specifies the Limit Stop part number or the part class to use for the support.

Use the following part class ProgID types:

1- RichHgrBeam

2 - TwoStandardPort

3 - Guide

4 - Pipe Clamp

IJUAhs_StopSide::StopSide

Specifies a codelist value that decides where to place the Limit Stop.

hsSupSide:

1 - One side

2 - Both sides

IJUAhs_StopToggle::
StopToggle

Specifies the codelist value to toggle the side on which the Limit Stop is placed.

The StopToggle value is ignored if the Limit Stop is placed on both the sides.

To set the correct orientation, adjust Angle1 when you toggle.

hsStopSideToggle:

1 - Side 1

Illustration of Limit Stop Attribute - IJUAhs_StopToggle - Side 1

2 - Side 2

Illustration of Limit Stop Attribute - IJUAhs_StopToggle - Side 2

IJUAhs_StopClearance::
StopClearance

Specifies the space between the edge of the supporting steel and the Limit Stop.

The StopClearance value depends on the Structure Connection.

If Structure Connection is equal to 1, clearance is calculated as the space between the edge of the supporting steel and Limit Stop.

If Structure Connection is equal to 2, clearance is measured using a starting point as 0.

If Structure Connection is equal to 0, the Limit Stops are placed against the supporting steel or against each other. A positive value for the Structure Connection increases the space between the Limit Stops.

Use the following definitions:

1 - Structure Connection

Illustration of Limit Stop Attribute - IJUAhs_StopClearance - Structure Connection 1

2 - Structure Connection

Illustration of Limit Stop Attribute - IJUAhs_StopClearance - Structure Connection 2

IJUAhs_StopStiffPart::StiffenerPart

Specifies the stiffner part or uses the stiffner partclass.

Use the following part class ProgID types:

1 - Plate Part

2- RPad

For more information on how to use part attributes and dimensional attributes, see Part Specifications and Input Values.