IJUAhsFrameLength1::Length1Value - Specifies the length of the first leg after the support is placed. This property is set by the AIR and can be used for reporting purposes or for the support validation.

IJUAhsFrameLength1Def::Length1Definition - Defines where the length should be measured from. This property sets the definition of Length1Value. Allowed values are as follows:

  • 1 - End of Steel

  • 2 - End of Plate

  • 3 - Pipe Center line

Braced Cantilevers

The following properties are applicable to only braced cantilevers:

IJUAhsFrameLength2::Length2Value - Specifies the length of the brace leg after the support has been placed. This property is set by the AIR and can be used for reporting purposes or for support validation.

IJUAhsFrameLength2Def::Length2Definition - Defines where the length should be measured from. This property sets the definition of Length2Value. Allowed values are:

  • 1 - Cut Length