CL330, CP Type/Termination/Preparation (999) - PDS - Help

Plant Design System (PDS) Stress Analysis Interface (PD_Stress)

PPMProduct
PDS
PPMCategory_custom
Help

Use 2-199 for bolted types; 300-399 for male types and
400-599 for female types. Refer to Reference Data Manager
(PD_DATA) Reference Guide for additional data.


1 = [Blank]

2 = 'FE' [Flanged end]

Use 11-15 for ends without integral gaskets; 16-19 for ends with
integral gaskets.
10 = 'FFTP (11-19)' [Flat-face flanged termination type]
11 = 'FFFE' [Flat-face flanged end]
16 = 'FFFEWG' [Flat-face flanged end with integral gasket]

Use 21-25 for ends without integral gaskets; 26-29 for ends with
integral gaskets.
20 = 'RFTP (21-29)' [Raised-face flanged termination type]
21 = 'RFFE' [Raised-face flanged end]
26 = 'RFFEWG' [Raised-face flanged end with integral gasket]

Use 31-35 for ends without integral gaskets; 36-39 for ends with
integral gaskets.
30 = 'RJFTP (31-39)' [RTJ-face flanged termination type]
31 = 'RJFE' [RTJ-face flanged end]

Use 41-45 for ends without integral gaskets; 46-49 for ends with
integral gaskets.
40 = 'TMFTP (41-49)' [Tongue/male-face flanged termination type]
41 = 'STFE' [Small-tongue-face flanged end]
42 = 'LTFE' [Large-tongue-face flanged end]
43 = 'SMFE' [Small-male-face flanged end]
44 = 'LMFE' [Large-male-face flanged end]

Use 51-55 for ends without integral gaskets; 56-59 for ends with
integral gaskets.
50 = 'GFFTP (51-59)' [Groove/female-face flanged termination type]
51 = 'SGFE' [Small-groove-face flanged end]
52 = 'LGFE' [Large-groove-face flanged end]
53 = 'SFFE' [Small-female-face flanged end]
54 = 'LFFE' [Large-female-face flanged end]

Use 61-65 for lap-flanged ends without integral gaskets; 66-69 for
lap-flanged ends with integral gaskets.
60 = 'FFLFTP (61-69)' [Flat-face lap-flanged termination type]
61 = 'FFLFE [Flat-face lap-flanged end]

Use 71-75 for lap-flanged ends without integral gaskets; 76-79 for
lap-flanged ends with integral gaskets.
70 = 'RFLFTP (71-79)' [Raised-face lap-flanged termination type]
71 = 'RFLFE' [Raised-face lap-flanged end]

Use 81-85 for lap-flanged ends without integral gaskets; 86-89 for
lap-flanged ends with integral gaskets.
80 = 'RJFLFTP (81-89)' [RTJ-face lap-flanged termination type]
81 = 'RJLFE' [RTJ-face lap-flanged end]

Use 91-95 for lap-flanged ends without integral gaskets; 96-99 for
lap-flanged ends with integral gaskets.
90 = 'TMFLFTP (91-99)' [Tongue/male-face lap-flanged termination type]
91 = 'STLFE' [Small-tongue-face lap-flanged end]
92 = 'LTLFE' [Large-tongue-face lap-flanged end]
93 = 'SMLFE' [Small-male-face lap-flanged end]
94 = 'LMLFE' [Large-male-face lap-flanged end]

Use 101-105 for lap-flanged ends without integral gaskets; 106-109
for lap-flanged ends with integral gaskets.
100 = 'GFFLFTP (101-109)'[Groove/female-face lap-flanged termination type]
101 = 'SGLFE' [Small-groove-face lap-flanged end]
102 = 'LGLFE' [Large-groove-face lap-flanged end]
103 = 'SFLFE' [Small-female-face lap-flanged end]
104 = 'LFLFE' [Large-female-face lap-flanged end]

Use 111-115 for ends without integral gaskets; 116-119 for ends
with integral gaskets.
110 = 'FFTBTP (111-119)'[Flat-face thru-bolted termination type]
111 = 'FFTBE' [Flat-face thru-bolted end]
116 = 'FFTBEWG' [Flat-face thru-bolted end with integral gasket]

Use 121-125 for ends without integral gaskets; 126-129 for ends
with integral gaskets.
120 = 'RFTBTP (121-129)'[Raised-face thru-bolted termination type]
121 = 'RFTBE' [Raised-face thru-bolted end]
126 = 'RFTBEWG' [Raised-face thru-bolted end with integral gasket]

Use 131-135 for ends without integral gaskets; 136-139 for ends
with integral gaskets.
130 = 'RJTBTP (131-139)'[RTJ-face thru-bolted termination type]
131 = 'RJTBE' [RTJ-face thru-bolted end]

Use 141-145 for ends without integral gaskets; 146-149 for ends
with integral gaskets.
140 = 'MRJTBTP (141-149)'[Male RTJ-face thru-bolted termination type]
146 = 'MRJTBEWG' [Male RTJ-face thru-bolted end with integral gasket]

Use 151-155 for ends without integral gaskets; 156-159 for ends
with integral gaskets.
150 = 'FFTBCSTP (151-159)'[Flat-face thru-bolted-with-cap-screws termination type]
151 = 'FFTBCSE' [Flat-face thru-bolted-with-cap-screws end]
156 = 'FFTBCSEWG' [Flat-face thru-bolted-with-cap-screws end with integral gasket]

Use 161-165 for ends without integral gaskets; 166-169 for ends
with integral gaskets.
160 = 'RFTBCSTP (161-169)'[Raised-face thru-bolted-with-cap-screws termination type]
161 = 'RFTBCSE' [Raised-face thru-bolted-with-cap-screws end]
166 = 'RFTBCSEWG' [Raised-face thru-bolted-with-cap-screws end with integral gasket]

Use 171-175 for ends without integral gaskets; 176-179 for ends
with integral gaskets.
170 = 'RJTBCSTP (171-179)'[RTJ-face thru-bolted-with-cap-screws termination type]
171 = 'RJTBCSE' [RTJ-face thru-bolted-with-cap-screws end]

Use 181-185 for ends without integral gaskets; 186-189 for ends
with integral gaskets.
180 = 'FFFTBTP (181-189)'[Flat-full-face thru-bolted termination type]
181 = 'FFFTBE' [Flat-full-face thru-bolted end]
186 = 'FFFTBEWG' [Flat-full-face thru-bolted end with integral gasket]

190 = 'MJTP (190-199)'[Mechanical joint termination type]
191 = 'MJE' [Mechanical joint end]

300 = 'MTP (301-399)'[Male termination type]

Use 301-309 for welded ends only
301 = 'BE' [Beveled end]
302 = 'OLET' [Olet beveled end]

Use 311-319 for welded ends only
311 = 'TBE' [Tapered and beveled end]
321 = 'MFE' [Male flared end]
331 = 'MTE' [Male threaded end]
341 = 'MGE' [Male grooved end]
351 = 'MQCE' [Male quick connect end]
355 = 'MCE' [Male clamp end]
361 = 'MFRE' [Male ferrule end]
371 = 'MHE' [Male hose end]
381 = 'SPE' [Spigot end]

Use 391-399 for welded ends only
391 = 'PE (391-399)'[Plain end]
393 = '3"FFPE' [Plain end, 3" field fit]
395 = '6"FFPE' [Plain end, 6" field fit]

400 = 'STP (401-409)'[Socket termination type]
401 = 'SE' [Socket end]

Use 421-429 for welded ends only
420 = 'SWTP (421-429)'[Socketwelded termination type]
421 = 'SWE' [Socketwelded end]

440 = 'FTTP (441-449)'[Female threaded termination type]
441 = 'FTE' [Female threaded end]

460 = 'FGTP (461-469)'[Female grooved termination type]
461 = 'FGE' [Female grooved end]

470 = 'FCTP (471-479)'[Female clamp termination type]
471 = 'FCE' [Female clamp end]

480 = 'FQCTP (481-489)'[Female quick connect termination type]
481 = 'FQCE' [Female quick connect end]

500 = 'FFRTP (501-509)'[Female ferrule termination type]
501 = 'FFRE' [Female ferrule end]

520 = 'FHTP (521-529)'[Female hose termination type]
521 = 'FHE' [Female hose end]

540 = 'BLTP (541-549)'[Bell end termination type]
541 = 'BLE' [Push-on bell end]
542 = 'MJBE' [Mechanical joint bell end]

590 = 'HTP (581-599)'[Hole end termination type]

Use 591-599 for welded ends only
591 = 'HCE' [Circular hole end]

600 = 'NTP (600-605)'[Null termination type]
601 = 'NE' [Null end]

650 = 'UDTP (651-659)'[User defined termination type]
651 = 'UD' [User defined end] (When a "UD"
preparation end is detected by the
system in the piping materials
class, it will prompt the User to define
the actual CP preparation to use. The
value provided by the User will be used
for initial placement of the component
as well as for subsequent recreations of
the piping system.)