Warning Messages - PDS - Help

Plant Design System (PDS) Stress Analysis Interface (PD_Stress)

PPMProduct
PDS
PPMCategory_custom
Help

Message

Message/Comment

W1

Reuse counter mismatch

The reuse counter stored in the design file does not match that stored in the database. This is potentially a serious problem that could indicate that components in the model are linked to incorrect database records. It is strongly recommended that the model be analyzed to determine the extent of the problem and to correct the situation.

W2

Standard note not found, default value used

This message indicates there was no note for the code list numbers and a blank (" ") was used. This can be fixed by placing a valid note into the Standard Note Library for that code list number.

W3

Unable to locate stress code, default code used

This message means that there was no match in the CODE NAME OF CODE PARAMETER DATA TABLE in the options file for the design_code_requirements attribute for the segment currently being extracted. The first record in the table was used instead.

W4

Unable to locate end prep, default end prep used

This message means there was no match in the END PREPARATION TABLE in the options file for the component which is currently being processed. The first record in the table was used to generate the end prep code.

W5

Component has undefined commodity code

This message indicates that the current component or pipe does not have a commodity code and a blank was used.

W6

Unable to locate fitting type, default fitting type used

This message means there was no match in the FITTING NOMENCLATURE TABLE in the options file for the commodity code of the current component.

W7

Nominal piping diameter has been truncated

The text string generated from the nominal piping diameter has exceeded the maximum size allowed in the software and was truncated. Contact Intergraph.

W8

Unable to locate hanger type, default hanger type used

This means there was no match in the HANGER TYPE TABLE of the options file for the pipe_support_type attribute of the current pipe support/hanger and the first entry of the table was used.

W9

Reducer size table not found, default values used

This means there was no reducer size table found in the commodity library and default values were used for flare radius, length and cone angle. This can be fixed by modifying the RED_SIZE.TBL in the win32app\ingr\pdstress\dat directory to contain the needed information and place it into the commodity library.

W10

Wall thickness table not found, default values used

This message indicates there was no thickness table found in the commodity library for the current component and zero was used. This message usually occurs on components with schedule thicknesses set to NREQD.

W12

Outside Diameter attribute undefined - Insulation Unit Weight defaulted to 0.0

This means that Insulation Unit Weight can not be calculated because the outside diameter for the component or pipe being processed is undefined in the database. Check all components and pipes in the line being extracted to make sure the outside diameter has a valid value.

W13

Dry Weight attribute undefined - Dry Unit Weight defaulted to 0.0

This means that the dry weight attribute in the database is undefined. Check all components and pipes in the line being extracted to make sure the dry weight has a valid value.

W14

Wet Weight attribute undefined - Wet Unit Weight defaulted to 0.0

This means that the wet weight attribute in the database is undefined. Check all components and pipes in the line being extracted to make sure the wet weight has a valid value.