Message |
Message/Comment |
---|---|
E1 |
Error opening error message file - pdsstr.err An error occurred while trying to open the error message file. Check to make sure that the file pdsstr.err is not opened by another user in the default directory. |
E3 |
Error opening input data file - PDSSTR.DAT An error occurred while attempting to open the input file to the stress analysis interface. Check to make sure that the file PDSSTR.DAT exists in the default directory. |
E4 |
Word 11 in the INTERGRAPH OPTIONS BLOCK is undefined Word 11 in the options block must be set to 1. |
E5 |
No model files found in input data file - PDSSTR.DAT An error occurred generating PDSSTR.DAT or the user entered a blank first line in the input data file and no model file names were found. Check to make sure there are valid model file names in PDSSTR.DAT in the default directory. |
E6 |
No line names found in input data file - PDSSTR.DAT An error occurred generating PDSSTR.DAT or the user entered two blank lines between the last model file name and the first line name. Check to make sure there is only one blank line between the last model file name and the first line name in PDSSTR.DAT in the default directory. |
E7 |
Word 12 in the INTERGRAPH OPTIONS BLOCK is undefined Word 12 in the options block must be set to 1. |
E8 |
Error opening stress options file |
E9 |
Fatal SEQUENCER error An error occurred while organizing the design file components. Check the model design file to verify that the pipeline being extracted is free of modeling errors. If the pipeline is correct, contact Intergraph. |
E10 |
Error reading input data file - PDSSTR.DAT An error occurred reading information from the input data file. Check the record format of the input data file PDSSTR.DAT in the default directory. |
E11 |
Logical name STRESSOPTION is undefined or file does not exist |
E15 |
Number of connect points exceeded internal limit of 5000 connect points The maximum number of connect points per extraction is 5,000. Break the line into two separate line names and re-extract the line as two separate isometrics. |
E16 |
Error reading FORM type from options file An error occurred reading in the FORM type from a record in the ELEMENT PROPERTY / CONNECTIVITY TABLE section of the options file. Valid values for form type are 0-6. For more information on property and connectivity record refer to the Options File section. |
E17 |
Error reading database occurrence An error occurred in trying to read a record from the database on a design file linkage. This error indicates potentially serious problems in the model. It is strongly recommended that the model be analyzed to determine the extent of the problem and to correct the situation. |
E18 |
Error retrieving DDL pair This message means that an error occurred trying to read an attribute from the database. Check the database DDL to make sure the DDL pair in question consists of a valid entity and attribute number. |
E19 |
Error retrieving DDL table An undefined entity number has been read in from either the LOADING DATA (LOAD) TABLE, the SERVICE LOADING (LSET) TABLE or the ELEMENT PROPERTY / CONNECTIVITY TABLE in the options file. Check to make sure only valid entity numbers are used in the DDL pairs section of the above tables. |
E20 |
Error writing CODE record An error occurred while trying to write a CODE record to the STRESS ANALYSIS neutral file. |
E21 |
Error converting Segment occurrence number from decimal to hex An error occurred while trying to convert a Segment occurrence number from decimal format into a hexadecimal format. Contact Intergraph. |
E22 |
Error writing header information into neutral file An error occurred while trying to write the header records to the beginning of the stress analysis neutral file. |
E23 |
Error writing DRAW record An error occurred while trying to write a DRAW record to the stress analysis neutral file. |
E24 |
Error converting nominal piping diameter This message means there was an error trying to convert the nominal piping diameter from the database format to an ASCII format. Contact Intergraph. |
E25 |
Error loading record from options file |
E26 |
Invalid table for Insulation Weight An error occurred trying to retrieve insulation weight for a table which does not have an insulation weight attribute. Verify that the DDL pair "0,-3" or "0,-4" is not any of the pipe support/hanger records in the ELEMENT PROPERTY / CONNECTIVITY TABLE section of the options file. |
E27 |
End node number is too small for current line An error occurred trying to assign an end node number to the current line being extracted. This can be fixed by increasing the end node number (word 3) of the INTERGRAPH OPTIONS BLOCK section of the options file. |
E28 |
Internal table limits exceeded for PDS to STRESS map The internal table size for the PDS to STRESS map has reached its limits and the remainder of the map can not be stored. Reduce the number of records in the PDS to STRESS map. Contact Intergraph for information about increasing the maximum table size. |
E29 |
Error initializing spec table access information An error occurred while trying to open and initialize the piping job specification tables. Check the project files to make sure they exist and you have read access to them. |
E30 |
Error reading record from options file An error occurred while trying to read a record from the options file. Check the bad record to make sure it is in the proper format. |
E31 |
Error opening neutral file An error occurred while trying to open the stress analysis output neutral file. |
E33 |
No component was found that matches the database search criteria An error occurred while trying to use the pipeline name keyin value. Either the value is missing, or word 12 is set incorrectly. |
E34 |
Error writing LNOD record An error occurred trying to write a LNOD record to the stress analysis neutral file. |
E35 |
Error searching for PDS item name in PDS to stress analysis symbol map An error occurred searching for PDS item name in the PDS to stress analysis symbol map. Check to make sure hte PDS item name is in the PDS to STRESS table. |
E36 |
Undefined generic name in PDS to STRESS map An error occurred in reading the generic name from the PDS to stress analysis symbol map. Check to make sure that the generic name is defined in the table. |
E37 |
Error locating PROPERTY/CONNECTIVITY records for generic name An error occurred searching for the PROPERTY / CONNECTIVITY record(s) from the ELEMENT PROPERTY / CONNECTIVITY TABLE section of the options file. Check to make sure all the necessary form records are in this table. |
E38 |
Error reading standard note library An error occurred while reading the standard note library. Check the standard note library to make sure the standard note exists. |
E39 |
Error writing LSET record An error occurred while trying to write a LSET record to the neutral file. |
E40 |
Error writing NODE record An error occurred while trying to write a NODE record to the neutral file. |
E41 |
Error writing CONNECTIVITY record An error occurred while trying to write a CONNECTIVITY record to the neutral file. |
E42 |
Error writing PROPERTY record An error occurred while to to write a PROPERTY record to the neutral file. |
E43 |
Error accessing or opening PDS to STRESS map An error occurred while trying to open the PDS to stress analysis symbol map. Check to make sure the file exists and that you have read access to it. |
E44 |
Error reading PDS to STRESS map An error occurred while trying to read a record from the PDS to stress analysis symbol map. Check to make sure the table is in the correct format. |
E45 |
Error - line is composed of multiple disconnect section - number of sections: 2 An error occurred because your pipeline has a gap, or two separate pipelines have the same pipeline name or stress ID number. |
E46 |
Line does not contain a valid starting point An error occurred because a pipe support is at the end of the pipeline. |
E49 |
Error writing LOAD record An error occurred while trying to write LOAD record to the neutral file. |
E50 |
Error searching for segment occurrence number An error occurred while searching for the segment occurrence number from the current component. Check the model to make sure that components are owned by the correct segments. |
E51 |
Error accessing wall thickness table An error occurred while accessing information from the wall thickness table. Check the commodity library to make sure the wall thickness table exists. |