Defines the format of the HeatTreatment/NDE file, which must be defined using the Drawing Manager.Input Files.Heat Treatment property.
The HEATTREATMENT/NDE-FILE section heading is followed by the identifiers and associated data listed below:
-
DELIMITER-CHARACTER specifies the delimiter used in the pipeline attribute file. (Optional).
-
IGNORE_CHARACTER specifies any character that should be ignored when the application is extracting data for the pipeline attribute file if it is a delimited file. (Optional).
The data items are the -900 to -999 series text type record identifiers, followed by start-col. end-col. or position in file, depending on whether a delimiter character is set. The data after the ! character is a comment for user information.
FUNCTION-DEFINITION-FILE
HEATTREATMENT/NDE-FILE
DELIMITER-CHARACTER ,
-950 2 ! PWHT N.S. RANGE
-951 3 ! PWHT TEMPERATURE
-952 4 ! PREHEAT N.S RANGE
-953 5 ! PREHEAT TEMPERATURE
-954 6 ! % RT
-955 7 ! % MT
-956 8 ! % PT
-957 9 ! % BHN