COMPONENT-INFORMATION-SELECTION section - Isogen - Help

Isogen Configuration Help

Language
English
Product
Isogen
Search by Category
Help
I-Configure Version
6.0(2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Provides a link between the design contractor's item code that appears in the Piping data file and the location of the corresponding entry for that component in the COMPONENT-INFORMATION-FILE.

This FDF section defines:

  • Design contractor's item code

  • Alternative item code

  • Alternative description

The section heading COMPONENT-INFORMATION-SELECTION is followed by the identifiers listed:

ITEM-CODE-INPUT data

ITEM-CODE-OUTPUT data

DESCRIPTION data

Where data is either a start column or file position, depending on whether the component information file is a delimited file. The minimum requirement in this section is the input item code:

COMPONENT-INFORMATION-SELECTION (section identifier)

ITEM-CODE-INPUT 1

Alternatively, if item code transposition and material description substitution are being used, the file resembles the example below:

COMPONENT-INFORMATION-SELECTION section identifier)

ITEM-CODE-INPUT 1

ITEM-CODE-OUTPUT 51

DESCRIPTION 76

Or for a delimited file:

COMPONENT-INFORMATION-SELECTION(section identifier)

ITEM-CODE-INPUT   1

ITEM-CODE-OUTPUT   7

DESCRIPTION   10