Assign Post Weld Heat Treatment requirements for a piping class - Intergraph Smart WQMS - 5.0 - Help - Hexagon PPM

Intergraph Smart Weld Quality Management System Help

Language
English
Product
Intergraph Smart WQMS
Search by Category
Help
Smart WQMS Version
5.0

Post Weld Heat Treatment (PWHT) is performed on a weld to ensure the material strength of a weld is retained after the welding process. This module is used to assign PWHT requirements for a piping class.

  1. Click Administration > Reference Data.

  2. Click PWHT Requirements.

  3. Click Add Item .

  4. Enter the following information:

    • Piping Class

    • IsPWHTRequired

  5. Enter the piping class and select NA (Not Applicable) or Y (Yes) from IsPWHTRequired list for the piping class.

  6. Select the piping class and click Assign PWHT . This information is updated in Piping > Welds module.