Open WQMS-Admin Excel file.
-
Navigate to ColumnSet sheet > SPFColumnSet section and edit the following properties:
-
UID - Type a unique identifier for the column set in the UID syntax.
-
Name - Type a name for the column set.
-
Description - Provide a short description to explain the purpose of the column set.
-
WQMSGridDataLoadExtraObjects - Specify the UID for LoadMappingDef. To create a UID, refer to Create or modify additional objects while loading data from Excel.
-
WQMSDefaultSearchCriteriaOnModule - This property defines the criteria for search in the WQMS UI.
-
WQMSAutoCalculateObjects - This property specifies the auto calculation method for the column set. For more details about how to edit auto calculations properties, refer to Calculate column-item values with specific conditions.
-
WQMSCalculateSecENSSequence - This is the secondary ENS sequence. Any secondary ENS which is defined on a property must be assigned here to invoke the ENS criteria.
-
WQMSQueryCriteria - This property defines the criteria to query data and display in the reports. Use this property only while generating reports.
-
ContainerID - Defines the package or .xml file that contains the object.
-
Solution(s) - Type * to load the data to SPF database, or type Deleted to avoid loading the data to SPF database.
-
-
Save the file.
-
Open WQMS-Modules Excel file.
-
Navigate to ModuleSpecificProperties sheet > UpdateInstruction section.
-
In the Column Set, provide the UID that you created or modified in WQMS-Admin Excel file against the relevant module RefUID.
-
Save the file.
-
To create or modify column sets for Reference Data submodules, use WQMS_ReferenceData_Admin Excel file instead of WQMS-Admin Excel file.
-
All column items related to a column set must belong to a unique ClassDef.