Modify module properties - Intergraph Smart WQMS - 6 - Administration & Configuration - Hexagon PPM

Intergraph Smart Weld Quality Management System Administration

Language
English
Product
Intergraph Smart WQMS
Search by Category
Administration & Configuration
Smart WQMS Version
6
  1. Open the WQMS-Modules Excel file.

  2. Navigate to WQMS Modules sheet > WQMSAdminModule section, modify the following properties:

    • UID - Type a unique identifier for the module in the UID syntax.

    • Name - Type a name for the module.

    • Description - Provide a short description to explain the purpose of the module.

    • WQMSModuleName - Type a name for the module to display in the UI.

    • WQMSModuleDisplayDescription - Provide the tool tip for the module.

    • WQMSModuleImage - Specify the icon name for the module. You can use only the existing icons within the module.

    • WQMSModuleViewClass - Specify the view class (Column-set and Column-items) for a module or submodule.

    • Solution(s) - Type * to load the data to SPF database, or type Deleted to avoid loading the data to SPF database.

    • ContainerID - Defines the package or .xml file that contains the object.

  3. Save the file.