Defines the distance from or destination to which the model is moved. While defining the destination coordinates, keep in mind that they are relative to the reference origin (where the model started out).

Reference origin

North

Specifies the north coordinate for the move reference origin.

East

Specifies the east coordinate for the move reference origin.

Elevation

Specifies the elevation coordinate for the move reference origin.

Pick Point

Selects a 3D point in the model using the mouse rather than typing specific coordinate values. For more information, see Placing 3D Points.

Pick the reference origin before you transform the model position.

Destination

Absolute

Switches the move coordinate fields to accept absolute destination values for the new model position. This option allows you to move the display set a specified amount from the original reference point.

Use the Absolute option to see the same values as those entered in the Destination Values in Smart Interop Publisher.

Delta value

Switches the move coordinate fields to accept delta offset values for the new model position. The Delta options allow you to define an offset, either a specified amount or a distance and bearing, from the original reference point.

Delta direction

Switches the move coordinate boxes to accept delta directional offset values for the new model position. The Delta options allow you to define an offset, either a specified amount or a distance and bearing, from the original reference point.

North

Specifies the absolute destination delta value or delta direction for the north coordinate for the new position.

East

Specifies the absolute destination delta value or delta direction for the east coordinate for the new position.

Elevation

Specifies the absolute destination delta value or delta direction for the elevation coordinate for the new position.

Pick Point

Specifies a 3D point in the model for the destination point rather than specifying each coordinate individually.