Thickness Table - Intergraph Smart Reference Data - 2020 10.0 - Customization & Programming - Hexagon

Intergraph Smart Reference Data Integration (2020)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Customization & Programming
Smart Materials/Smart Reference Data Version
2020 (10.0)

The thickness table fields that are used in CADWorx are listed below.

  • NOM - Nominal Pipe Size - The size of the component from the size table. The export provides the value from SRD using the NOM attribute.

  • Schedule types - The values in this area are schedule table values associated with the thickness table. They represent the weight and thickness of the component. The export provides the values from SRD.

As the list of columns may be different, each thickness table will result in a separate file. The thickness table name is the last part of the file name after the keyword ThicknessTable and a $ symbol. Below you find an example of a thickness file name:

CDWRX_EJ_0000018630_ThicknessTable$THK.lst

with CDWRX indicating the product (CADWorx) and EJ_nnnnnnnnnn indicating the SRD export job number.

The thickness table name is not specified in the list of columns; the number of rows and the number of columns may vary, depending on the participating nominal sizes and schedules.

A thickness table needs a size table name and a schedule table name as references, so these table names appear in the first two columns, as shown in the sample below:

SIZE_TABLE|SCHEDULE_TABLE|NOM|5S|5|10S|…

Size|SCH|.125|0|.035|.049|…

The initial version of the interface supports template copy for customers who maintain the wallthickness table on CADWORX 10.08.