Operator - Intergraph Smart Reference Data - 2020 10.0 - Customization & Programming - Hexagon

Intergraph Smart Reference Data Integration (2020)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Customization & Programming
Smart Materials/Smart Reference Data Version
2020 (10.0)

The definition of the ball valve itself is complete, and now the operator must be configured.

Operator Type 10005 is needed, with SymbolDefinition Operator10005.COperator10005.

0.5 - 1.25in

Operator Height = Valve Height + 0.525in

OpDim1 = 1.5in

1.5 - 3in

Operator Height = Valve Height + 0.7in

OpDim1 = 2in

4 - 6in

Operator Height = Valve Height + 1.05in

OpDim1 = 3in

8in - 10in

Operator Height = Valve Height + 1.4in

OpDim1 = 4in

For the operator definition, these following sheets are needed and must be defined or updated:

Operator10005

PipingCommodityMatlControlData

ValveOperatorMatlControlData