SmartPlant P&ID Options Manager Settings
You can now use specifications on a drawing in SmartPlant P&ID. The specifications are defined in Smart Reference Data server.
The following reference data settings are defined using SmartPlant P&ID Options Manager to specify the location of particular types of data. You can specify various default settings used in creating P&IDs and sharing data with other applications, like Smart Reference Data.
-
Enable piping specification validation — Invokes continuous service limits validation and automatic commodity code lookup if the Use piping specification setting is Smart Reference Data and this setting is Yes.
-
SmartPlant Reference Data plant name — Specifies the name of the Smart Reference database.
-
SmartPlant Reference Data server name — Specifies the server that contains the Smart Reference Data database.
Configure PipeSpec Settings
-
In SmartPlant P&ID Options Manager, click Settings.
-
In the Enable piping specification validation list, select Yes.
-
In the Use piping specification list, select Smart Reference Data.
-
Fill in the database information in the Smart Reference Data Plant Name and Smart Reference Data Server Name boxes.
1 |
Yes |
2 |
SmartPlant Reference Data Plant Name - Project or the Product Group name of the Smart Reference data. SmartPlant Reference Data Server Name - Node or the machine name where Smart Reference Data Oracle Database is installed. For example, if the Smart Reference Data Oracle database is installed on IN-SPMATDBSRV, with the Oracle SID, SDB2012, type IN-SPMATDBSRV:1521/SDB2012. 1521 is the default Oracle listener port. |
3 |
SmartPlant Reference Data |
Configure ProgIDs
-
Click Start > SPEM > Data Dictionary Manager.
-
Click Database Tables.
-
Click each database table listed in the following table.
Database Table |
Property |
Calculation ID |
Validation ID |
---|---|---|---|
Case Process |
Pressure |
PipeSpec.CommodityCodeValidator |
|
Case Process |
Temperature |
PipeSpec.CommodityCodeValidator |
|
Inline Component |
Nominal Diameter |
ValidateNomDiam.ForeignCalc |
|
Inline Component |
Commodity Code |
PipeSpec.CommodityCode Validator |
|
Pipe Run |
Piping Materials Class |
PipeSpec.PMCFinder |
PipeSpec.CommodityCodeValidator |
*Pipe Run |
Nominal Diameter |
PipeSpec.NPDFinder |
|
*Pipe Run |
SP_PipeSpecRevision |
PipeSpec.CommodityCodeValidator |
|
*Piping Component |
Option Code |
PipeSpec.OptionCodeFinder |
PipeSpec.CommodityCodeValidator |
Apply Specs of Smart Reference Data server
-
Log on to SmartPlant P&ID.
-
Open a drawing and select a piping component.
-
From Properties pane, select Piping Materials Class and then click . All the specifications for the connect project from Smart Reference Data area displayed.
-
Select a specification and then click Ok.