FlangeSetbkDistDataUndefined Report - Intergraph Smart Reference Data - Version 10.1 - Customization & Programming - Hexagon

Intergraph Smart Reference Data Integration (10.1)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Customization & Programming
Smart Materials/Smart Reference Data Version
10.1

The project default ZI_SP3D_CT must be assigned to a Smart 3D template for codelists in order to execute this report.

The FlangeSetbkDistDataUndefined verification report checks whether the set back distance is defined for the slip-on flange that is selected in the transfer job or that is in the destination.

All selected idents of the job are checked to determine if they appear in part classes in the export operation or in the destination. Otherwise, it is an error.

For all idents found in the part class, with the commodity type fetched from the part class, the sub class is determined from the piping commodity type codelist. This way, slip-on flanges are found. If no slip-on flanges are found, the check is skipped.

For each exported slip-on flange, the size and end standard for each port are checked.

Each size and end standard of the rows found in the previous step must have a matching entry on the SlipOnFlangeSetbackDistance sheet. Otherwise, it is an error.

If the SlipOnFlangeSetbackDistance sheet was not found at all (when slip-on flanges are used), it is reported for the first occurrence of failure only.