The project default ZI_SP3D_CT must be assigned to a Smart 3D template for codelists in order to execute this report.

The BoltExtensionDataUndefined verification report checks whether bolt extension data is defined for the bolted components that are selected on the transfer job screen or that are in the destination.

First, the IdentsNotInPartClass check is started, and misses are reported, even if the IdentsNotInPartClass verification was not included by the user.

If an ident is found, all of its bolted ends in BoltExtensionDataUndefined are reported whenever a bolt extension record is not found with size, unit, end preparation, pressure rating, and end standard.