Configure Piping Specification Settings - Intergraph Smart P&ID - 11.0 - Help - Intergraph

Intergraph Smart P&ID Utilities Help

Language
English
Product
Intergraph Smart P&ID
Subproduct
Smart P&ID Utilities
Search by Category
Help
Smart P&ID Version
11
Smart Engineering Manager Version
12
  1. In Smart P&ID Options Manager, click Settings.

  2. To enable continuous service limit validation and automatic commodity code lookup, do the following:

    1. In the Enable piping specification validation field, select Yes.

    2. In the Use piping specification field, select the PDS3D, Smart 3D, or Smart Reference Data option, depending on the type of 3D database to which you are connected.

    3. Enable the Calc buttons for the Piping Materials Class and Commodity Code properties by assigning Calculation IDs in Data Dictionary Manager. For details, see the Smart P&ID Utilities Guide topic, Enter Required ProgIDs.

    • If the Use piping specification setting is PDS3D, Smart 3D, or Smart Reference Data and the Enable piping specification validation setting is No, continuous service limits validation and automatic commodity code lookup are not available. However, the user can still manually select the Calc PPM All Outputs Graphic buttons to activate the Commodity Code Lookup dialog box or the Piping Materials Class selection dialog box.

    • If the Use piping specification setting is No, continuous service limits validation and automatic commodity code lookup are not available. Also, the Calc buttons for the Piping Materials Class and Commodity Code properties are not functional.

    • The Short Value entries in the Piping Component Type select list in Data Dictionary Manager are populated from the contents of the PDS3D_SP3D_ShortCode_Correlation.txt file (located in the ..\SmartPlant\P&ID Workstation\bin folder) according to the Use Piping Specification setting as follows:

      • PDS3D — The Short Value column is populated with data from the second column of the PDS3D_SP3D_ShortCode_Correlation.txt file (AABBCC code).

      • Smart 3D or Smart Reference Data — The Short Value column is populated with data from the third column of the PDS3D_SP3D_ShortCode_Correlation.txt file.

      • No — The data in the Short Value column is not updated and remains what it was previously.

    • When changing the Use piping specification setting from No to PDS3D, Smart 3D, or Smart Reference Data, validation occurs only for items modified after the change.

  3. Do one of the following:

    • If connecting to a Smart 3D database, fill in the database information in the Smart 3D Plant Name and Smart 3D Server Name fields, and then skip the rest of this procedure.

    • If connecting to a Smart Reference Data database, fill in the database information in the Smart Reference Data Plant Name and Smart Reference Data Server Name fields, and then skip the rest of this procedure.

      The Smart Reference Data server name must be entered as a connection string in the form of <Host Name>:<TCP/IP Port Number>/<Service Name>, for example:

      IN-SPMATDBSRV:1521/SDB2012

    • If connecting to a PDS 3D database, proceed with the remaining steps of this procedure.

  4. Select the database type from the PDS Database Type list. Supported database types are MSSQL and Oracle.

  5. Type the database name in the PDS Database Name field.

    SHARED Tip The database name is not required for Oracle databases. The default value of a blank space, not a null, must be assigned for Oracle databases.

  6. Type a value in the PDS Database Server/Alias field.

    SHARED Tip This entry defines the server name for a Microsoft SQL Server database or the Alias name on the client machine for an Oracle database.

  7. Type the user name and password of the ra schema of a PDS 3D project under PDS Approved Reference DatabaseSchema Name and PDS Approved Reference Database Schema Password respectively.

  8. Type the user name and password of the pd schema of a PDS 3D project under PDS Project Control Database Schema Name and PDS Project Control Database Schema Password respectively.

  9. In the Max-Temperature Unit in PDS3D list, select the unit of measurement used in PDS 3D for the maximum temperature limit for piping components.