Click Start > SPEM > Data Dictionary Manager.
-
Click the Database Tables button.
-
Click each database table listed in the following table.
Database Table
Property
Calculation ID
Validation ID
Case
ProcessPressure
PipeSpec.CommodityCodeValidator
Case
ProcessTemperature
PipeSpec.CommodityCodeValidator
Inline Component
NominalDiameter
ValidateNomDiam.ForeignCalc
Inline Component
CommodityCode
PipeSpec.CommodityCodeValidator
Pipe Run
PipingMaterialsClass
PipeSpec.PMCFinder
PipeSpec.CommodityCodeValidator
*Pipe Run
NominalDiameter
PipeSpec.NPDFinder
ValidateNomDiam.ForeignCalc
*Pipe Run
SP_PipeSpecRevision
PipeSpec.CommodityCodeValidator
*Piping Component
OptionCode
PipeSpec.OptionCodeFinder
PipeSpec.CommodityCodeValidator
The Calculation IDs for the Nominal Diameter and SP_PipeSpecRevision properties in the Pipe Run table and the Option Code property in the Piping Component table (items marked with an (*) asterisk) are available only when the pipe specification source is Smart 3D or Smart Reference Data. These validations are not available when the piping specification source is PDS 3D.
-
Double-click each property to display the Modify Property dialog box (see example below).
-
Type the necessary information in the given fields as shown in the above table; then click OK to save and close.
-
Repeat the steps 3 - 5 above to update each database table.