In Windows Explorer, browse to the ..\SmartPlant\P&ID Workstation\bin folder and double-click servicepidsexe.exe.
The Service Pids utility can also be run from within a drawing, but open drawings (or drawings in a recreate state) cannot be repaired. To run the Service Pids utility from within an open drawing in Smart P&ID, click Tools > Custom Commands and then, on the Custom Command dialog box, browse to ..\SmartPlant\P&ID Workstation\bin and double-click servicepidsexe.exe.
-
On the Service Pids dialog box, click Show Drawings to display a list of all the drawings associated with the active plant.
-
Select the check boxes beside the drawings that you want to process.
Click Select All to select all the drawings of the active plant.
-
Do one of the following:
-
Click Repair & Report to start the reporting process and address problems found.
-
Click Report to start the reporting process.
-
The Report command only reports problems. Problems are addressed by running the Repair & Report command or opening the drawing and running the Repair Relationship Indicators utility (RepairRelIndCmd.dll).
-
The Status column of the Service Pids dialog box shows the current status of each drawing as follows:
-
The
status indicates that the drawing is being processed.
-
The
status indicates that the drawing was processed successfully.
-
The
status indicates that the drawing is either open or in a recreate state.
-
-
-
Click View Logfile to view the results of the reporting or repair process. The log file can be saved as a text file and printed.
-
Click Close to close the utility.