  1. Click Start > SPEM > Data Dictionary Manager.

  2. Click the Database Tables button.

  3. Click each database table listed in the following table.

    Database Table

    Property

    Calculation ID

    Validation ID

    Case
    Process

    Pressure

    PipeSpec.CommodityCodeValidator

    Case
    Process

    Temperature

    PipeSpec.CommodityCodeValidator

    Inline Component

    NominalDiameter

    ValidateNomDiam.ForeignCalc

    Inline Component

    CommodityCode

    PipeSpec.CommodityCodeValidator

    Pipe Run

    PipingMaterialsClass

    PipeSpec.PMCFinder

    PipeSpec.CommodityCodeValidator

    *Pipe Run

    NominalDiameter

    PipeSpec.NPDFinder

    ValidateNomDiam.ForeignCalc

    *Pipe Run

    SP_PipeSpecRevision

    PipeSpec.CommodityCodeValidator

    *Piping Component

    OptionCode

    PipeSpec.OptionCodeFinder

    PipeSpec.CommodityCodeValidator

    The Calculation IDs for the Nominal Diameter and SP_PipeSpecRevision properties in the Pipe Run table and the Option Code property in the Piping Component table (items marked with an (*) asterisk) are available only when the pipe specification source is Smart 3D or Smart Reference Data. These validations are not available when the piping specification source is PDS 3D.

  4. Double-click each property to display the Modify Property dialog box (see example below).

  5. Type the necessary information in the given fields as shown in the above table; then click OK to save and close.

  6. Repeat the steps 3 - 5 above to update each database table.