  1. Copy the ActuatorTypeAndSymbolName.ini file to the folder specified in Options Manager > Settings > Catalog Explorer Root Path. Otherwise, the default symbol file is used.

  2. In the Drawing Manager, open a site database and select a plant.

  3. Open the Data Dictionary Manager and edit the database tables as mentioned in the steps below:

  4. Select the Database Table for Inline Component.

  5. Right-click Actuator Type property and select Properties.

  6. Add the value SmartInstrValveProgram.ValidationFunc to the Validation ID field as follows:

  7. Select OK.

  8. Select the Database Item Type for Instrument.

  9. In the Validation Program field, replace PlantItemValidation.Validate with SmartInstrValveProgram.ValidationFunc as follows:

  10. Select OK.

  11. Select Save and exit Data Dictionary Manager.