Change the Default Placement of Heat Tracing for the Plant - Intergraph Smart P&ID - 10.0 - Help - Intergraph

Intergraph Smart P&ID Options Manager Help

Language
English (United States)
Product
Intergraph Smart P&ID
Search by Category
Help
Smart Electrical Version
10
Smart P&ID Version
10
Smart Engineering Manager Version
11
  1. Click Tracing PPM All Outputs Graphic.

  2. On the toolbar, select one of the four icons that affect the default placement of heat tracing for both horizontal and vertical lines in the P&ID.

    The following table describes the available options.

    Option

    Heat Tracing Placement

    Tracing Position Icon

    BottomLeft

    Below horizontal lines and to the left of vertical lines.

    PPM All Outputs Graphic

    BottomRight

    Below horizontal lines and to the right of vertical lines.

    PPM All Outputs Graphic

    TopLeft

    Above horizontal lines and to the left of vertical lines.

    PPM All Outputs Graphic

    TopRight

    Above horizontal lines and to the right of vertical lines.

    PPM All Outputs Graphic

The default placement applies to all heat tracing media in the current plant, but only affects the display appearance in drawings for media that are designated as single heat trace media.