Define Gapping Style - Intergraph Smart P&ID - 10.0 - Help - Intergraph

Intergraph Smart P&ID Options Manager Help

Language
English (United States)
Product
Intergraph Smart P&ID
Search by Category
Help
Smart Electrical Version
10
Smart P&ID Version
10
Smart Engineering Manager Version
11
  1. Click Gapping PPM All Outputs Graphic.

  2. Select the Line Type box in the empty last row of the Gapping table.

  3. Click PPM All Outputs Graphic to select a filter.

  4. On the Select Filter dialog box, click the filter you want.

    SHARED Tip If necessary, you can create a new filter for your gapped item. For more information, see Create a Simple Filter (see ) or Create a Compound Filter (see ).

  5. Click OK.

  6. In the Gapping Style box of this row, click the symbol you want to use to indicate gaps for lines in the selected filter.

  • Options set for gapping in Smart P&ID Options Manager apply only to automatically gapped lines.

  • When you select a filter from the Line Type list, two filters appear in the Gapping table: one with vertical orientation and one with horizontal orientation. You can specify a gapping style for each.