Allows you to define the criteria used to search for out-of-date values when you use the File > Out-of-Date Drawings commands.
Select out-of-date drawing criteria
Select List Changes
Data Dictionary Select List GUID on the drawing item is not equivalent to select list GUID in Data Dictionary. PID Select List GUID on the drawing item is not equivalent to the select list GUID in PID schema.
Format Changes
Formats GUID on the drawing item is not equivalent to Formats GUID from the database. Default Formats GUID on the drawing item is not equivalent to Default Formats GUID in Options Manager setting.
Out-of-Date Symbols
File Last Modified Time Stamp on at least one representation in the drawing is not equivalent to the File Last Modified Time Stamp on the corresponding symbol definition file.
Missing Symbols
Filename specified for at least one representation in the drawing does not have the corresponding symbol definition file available in the current catalog.
Rule Changes
Rules GUID on the drawing item is not equivalent to the GUID from the Rules file.
Heat Trace Changes
Heat Trace GUID on the drawing is not equivalent to the Heat Trace GUID in Options Manager Setting.
Gapping Changes
Gapping GUID on the drawing item is not equivalent to the Gapping GUID in Options Manager Setting.
Symbology Changes
Symbology GUID on the drawing item is not equivalent to the Symbology GUID in Options Manager Setting.
Out-of-Date Model Items
SP_ModelItemTimeStamp for at least one representation in the drawing is not equivalent to the TimeStamp on the History Item of its Model Item. This criterion covers model items updated via Llama (outside the drawing).
Moved OPCs
MatingOPCPath (will have Drawing ID of its mate) on the OPC is not equivalent to the SP_DrawingId of its mate OPC. The OPC label is in a to-be-updated state as its mate has been moved.
Recreate State
The drawing is in a re-create state.
Drawing Property Changes
Property Changes GUID on the drawing item is not equivalent to Drawing Property Changes GUID on the drawing item. Drawing Property Changes GUID is set when drawing properties are modified from Drawing Manager.