Using Custom Hierarchies in an Integrated Environment - Intergraph Smart P&ID - 10 - Installation & Upgrade - Hexagon

Intergraph Smart P&ID Installation and Upgrade

Language
English
Product
Intergraph Smart P&ID
Search by Category
Installation & Upgrade
Smart P&ID Version
10

Integration supports custom hierarchies, as long as they contain a minimum of three levels. By default, the delivered SPEMdatamap.xml file is compatible with the standard Plant > Area > Unit hierarchy.

  • After registering, Smart Engineering Manager cannot retrieve the PBS document if the plant and SmartPlant hierarchies are not compatible. To be compatible with the SmartPlant hierarchy, your plant hierarchy can contain less than or equal, but not more than the number of levels in the SmartPlant hierarchy.

  • Smart Engineering Manager retrieves from the SmartPlant hierarchy only the hierarchy levels it needs. For example, if your plant hierarchy contains 4 levels and the SmartPlant hierarchy contains 8 levels, only the top 4 levels of the SmartPlant hierarchy are retrieved.

  • All Smart Engineering Manager hierarchy item names (plant group names) below the plant (top level) must match the names in the SmartPlant Foundation plant hierarchy that are at the same level. The names are case-sensitive and therefore the cases must also match. The plant names do not have to match.

  • In addition to requiring a minimum of three-levels in hierarchies, Integration also requires that the names of hierarchy items must not be changed after they are created and that the hierarchy structure must not be modified after you create the project.