Place a Break Label - Intergraph Smart P&ID - Help - Intergraph

Intergraph Smart P&ID Help

Language
English
Product
Intergraph Smart P&ID
Search by Category
Help
Smart P&ID Version
9 (2019)
Smart Engineering Manager Version
10 (2019)
SmartSketch Version
10.0(2018)
  1. From the List view in Catalog Explorer, select the break label that you want to place.

    SHARED Tip The Catalog Explorer Tree view node where break labels are located is called Segment Breaks.

  2. Place the break label using two-point placement. The first click (1) specifies the junction in the process line, the second click (2) designates the location for the break label itself.

    PPM All Outputs Graphic

  3. Continue placing the same break label at other junctions in the drawing, or press ESC to quit placement mode.

  • A break label can only be placed at a connection point where the specified properties are being propagated.

  • To place a break label on a valve located in the middle of a pipe run, you must first break the pipe run manually.

  • You can turn on or off the Is Leader Visible property in Catalog Manager. After you place the label, you can right-click the label, and then select Leader line display on the shortcut menu to control the display of the leader line in the drawing software.

  • Use care when you assign leader lines. You can place several break labels at one point, and multiple leader lines can be confusing.