To add the Smart Completions Integration command to the Smart P&ID toolbar, ensure that the Ingr.SPID.SmartCompletionCmd.dll is available in the _\Bin folder of the Smart P&ID installation path.
-
Open a drawing.
-
Right-click the main toolbar and select Customize.
-
On the Toolbars tab, select Custom Commands under Categories.
-
Under Custom Commands, select Ingr.spid.SmartCompletionCmd.dll and drag it to the toolbar.
-
In the Custom Button dialog, select a button and select Assign.
The Smart Completions Integration command will be available on the main toolbar.
See Customize Dialog and Custom Button Dialog, respectively.