Returning a Drawing to the Plant Using Check In - Intergraph Smart P&ID - 10 - Help - Hexagon

Intergraph Smart P&ID Drawing Manager

Language
English
Product
Intergraph Smart P&ID
Subproduct
Drawing Manager
Search by Category
Help
Smart P&ID Version
10

Checking in a drawing writes all of the changes made to the drawing by the project into the drawing stored in the Plant. When a drawing is checked in, all versions of that drawing are deleted from the project.

Verification Processes Performed During Check In

  • All objects that exist in the project but don't exist in the Plant must be claimed.

  • All objects that exist in the Plant but don't exist in the project (they were deleted) must have been claimed.

  • All objects that exist in both the Plant and the project must be identical if not claimed.

  • The claim state must be valid for the project.

  • If any claim on an object on this drawing is invalid, then check in cannot occur.

  • The timestamp on all objects that exist in the project must be earlier than or equal to the timestamp on the drawing.

  • Last Publish Date > Drawing date.

  • Check in is not allowed if drawing is in a Re-create state.

  • The Verify for Checkin command for new drawings should ensure that all items on the drawing have been claimed.

If an invalid claim is found but the item in question matches the item in the Plant, run Verify for Checkin to resolve this situation. This process automatically sets the claim to valid and allows the check in to occur.