To find the best match for a selected design element in 2D or 3D data, and correlate the elements manually follow the procedure below:

  1. Select a design element from the Design Hierarchy Explorer.

  2. On the Actions tab, click Manual Correlation.

    The software displays the Manual Correlation dialog box. If the correlation settings are set for the selected element, then a list of corresponding elements and percentage of match is displayed. For more information, see Manual Correlation Dialog Box.

  3. Click Correlate to correlate with the corresponding design element in the Design Hierarchy Explorer.

  • If the correlation settings are not set for the selected element, the following message is displayed:

    You need to set the correlation settings for Pipeline Systems to perform manual correlation.

  • If topology settings are set, then the match percentage for the leg is calculated based on these settings. Otherwise, only the basic topology is considered for finding the best match.

  • When you manually correlate the legs, the inconsistencies on those legs and corresponding components are cleared and re-calculated.

  • You can also right-click a design element in the Design Hierarchy Explorer and perform manual correlation.