If this check box is selected, the CIP procedures bolt_logic and gasket_logic in m_pck_pds_custom will be started.

Those procedures can be modified, if needed. They can also be called by a PDS 10.03 procedure.

The bolt_logic procedure does the following:

  1. Find the bolt lines in PCD (Zydex=6Q3C97).

  2. Set bolt's green size range to the minimum and the maximum used in the spec.

  3. Replace bolt's red size range by a minus.

  4. Find flanged material Zydex=6Q2C03, 6Q2C01.

  5. Duplicate bolt line for every different rating and tablesuffix of the flanges. The duplicated bolt line will get the rating and tablesuffix of the flange. If the rating is prefixed by "CL", this prefix is removed for the bolt rating.

  6. Delete any duplicate entries.

The gasket_logic procedure does the following:

  1. Find the bolt lines in PCD (Zydex=6Q3C97).

  2. Replace bolt's red size range by a minus.

  3. Find flanged material Zydex=6Q2C03, 6Q2C01.

  4. Duplicate bolt line for every different rating, tablesuffix, and endprep of the flanges. The duplicated bolt line will get the rating, tablesuffix, endprep, and minimum green size "from" and maximum green size "to" for this combination of the flange. If the rating is prefixed by "CL", this prefix is removed for the bolt rating.

  5. Delete any duplicate entries.